We are the leading manufacturers, exporters and suppliers of industrial products. Our Motor Rotor Testing System can give solutions to all testing problems simultaneously. In the production of this system, our engineers use the highest quality of components. Once these systems are manufactured, they are sent to the quality check department for clearing signal. Our Motor Rotor Testing System use DCR 4-wire measurement. There are control and analysis programs that reduce the human mistakes.
Features:
The MT6920 Motor Rotor Testing System puts the multi-channel specific fixture of the 6905, 6908 and the 6920 24/48 can integrate the testing problems together simultaneously. It performs as an edged equipment of inspection to manufacturing, engineering and quality control sectors.
Optional system is the Systematic Modular Cabinet Tester.
Standard system is the Super Space-Saving Desktops Tester.
Features
DCR | |
Range | 0.1m ~ 100K |
Accuracy | Low Resistance 0.1m ~ 1( 0.2% 1m) |
| High Resistance ~ 100K0.1% |
Hipot | |
Voltage | AC 0.1KV ~ 3KV DC 0.1KV ~ 3KV |
Leakage Current | AC 0 ~ 10mA DC 0 ~ 5mA |
Arcing | 0 ~ 9 |
Measurement Time | 0.1 ~ 99.9 Continuously Adjustable |
Accuracy | 3% |
IR | |
Voltage | 100V ~ 1000V 5% |
Range | 1M ~ 9.9G |
Measurement Time | 0.1 ~ 99.9 Continuously Adjustable |
Accuracy | 3% |
Short Circuit | |
Voltage | 0.2KV ~ 3KV 2% |
Measurement Item | Total Area Area size comparison Flutter Waveform comparison Corona |
Accuracy | 2% |
Using the DCR 4-wire Measurement
Both the internal wire resistance and the contact resistance will not affect the measurement. Using the 4-wire measurement will be more accurate than others.
Specification
Test Point | Depends on the Number of Slots that Matches with the Customer Products (Fixtures) |
Indicator | Pass/Fail Screen Display/Sound |
Fixture | According to the test requirements |
Power Supply | Voltage 90 ~ 132Vac or 198 ~ 264Vac (selectable) |
| Frequency 47-63Hz |
Interface | RS-232 |
Flash Memory | Storage of 100 rewritable data sets |
Operation | ManualRS-232 |
Environment | Temperature : 10C ~ 40C Humidity : 20 ~ 90% |
6905 (W*H*D) / Weight | 435x133x525 mm / 12.5 Kg |
6908 (W*H*D) / Weight | 435x133x525 mm / 7 Kg |
6920 (W*H*D) / Weight | 435x178x525 mm / 11 Kg |
6905 Display | 128*64 dot-matrix display |
6920 Display | 320*240 dot-matrix display |
Applications
Motor
![]() |
MICROTEST CORP.
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |